Overview › RS232


RS232/COM port

Use a Voltronic USB RS232 cable cable plugged into the inverter port labelled "RS232" or "COM".

Alternatively you can use the WiFi dongle cable with a USB serial cable You can read more about the communication chips we recommend using here, and the pin configuration below:
Pin 1RX
Pin 2TX
Pin 3-
Pin 4-
Pin 5-
Pin 6-
Pin 7-
Pin 8GND

Steps in SolarAssistant

On the configuration page, select "Sumry" as your inverter model.

SolarAssistant Sumry inverter selection

The cable you plugged in should show up as a USB port:

Select FTDI RS232 USB ports

Click connect:

Select connect

Parallel installations