InvertersSunSynk › 5kw Single Phase Hybrid
5kw Single Phase Hybrid
5kw Single Phase Hybrid
SunSynk
SUNSYNK-5K-SG01LP1
Automations Cloud bypass MQTT API Read via cable Read via network Real time Setting control
Overview › RS485

RS485 port

A purpose built USB RS485 cable can be plugged into the RS485 port located on the inside the inverter. This is an RS485 cable with a specific RJ45 pinout that can be purchased in our online store.

If you buy any random USB RS485 RJ45 cable on Amazon, Ebay, Takealot, etc. which doesn't specifically state that it supports the Deye inverter, it will most likely not work.

Deye RS485 cableDeye RS485 port

The labelling of the RS485 monitoring port is sometimes not intuitive. Please see the list below for the correct port.

Deye/SunSynk 5kW RS485 port

The BMS port is used for SolarAssistant monitoring and battery CAN communication at the same time. See the 2 in 1 BMS port

Steps in SolarAssistant

On the SolarAssistant configuration page, select "Deye, SunSynk, Sol-Ark" as your inverter model.

Select Deye inverter

Select the USB port where your inverter is connected. If you have multiple inverters, you need to multi-select multiple USB ports.

Select Deye USB adapters

Click connect:

Select connect

Parallel installations

With these inverters you will need to connect each inverter with its own cable.